If, for any reason, exhaust gases start coming back instead of going out, this can lead to improper gas combustion (yellow and red-ish burner flame, followed by the unstable pattern).

#Rinnai energysaver 1004f blinking red light code#

Venting, together with the unit installation, should be done by a qualified technician or a plumber and must follow the manufacturer’s specs, instructions, and code.Īn error code 12 might appear if the venting system has components not approved by the manufacturer, loose connections, or does not meet recommendations for the venting size, material, and clearances. If the flame rod or spark electrode has deposits (carbon buildup), use the fine grit paper and cloth to clean or Scotch Brite pad. If the water heater is working properly, the flame should have a clear, blue color with a stable pattern. The flame rod must be in contact with the flame to function correctly. Wires should be without any visible signs of damages or breakage and firmly attached to the rod and electronic board. Some Rinnai water heaters have two and some, one flame rod. The flame rod and the spark electrode (igniter) are firmly attached to the mounting bracket and should not be loose or misplaced. If the ceramic sleeve has cracks or is damaged, replace it. Disconnected or broken flame rodĬheck the status of the flame rod and that it is properly connected.

#Rinnai energysaver 1004f blinking red light professional#

Hire a professional to bleed all the air from the gas pipes.

rinnai energysaver 1004f blinking red light rinnai energysaver 1004f blinking red light

If the gas line has air in it, it needs to be purged. Gas interruptionĪn uninterrupted gas supply is vital for the regular water heater operation. Make sure that your model is using the proper fuel type, per specs. Tankless water heaters can use either natural gas or propane. You must contact a professional technician to fix the problem. Sometimes, due to improper sizing, the gas system is undersized (smaller diameter and insufficient regulator), leading to a higher pressure drop than per specs. Use the specs (found on the label attached to your water heater) to see the proper inlet pressure and check if the unit meets the minimum required. Your gas water heater should get enough amount of gas. If your tankless water heater uses propane, check if there is enough gas in the gas tank (cylinder). While the error 12 is a flame error code, the flame rod is not the only culprit - there are several other reasons for the flame failure: No gas supplyĬheck that all gas valves – on a water heater and gas pipes are open. If water is not equipped with the control panel, the same error code appears on the remote controller. You can see diagnostic information on the control panel, where you set the temperature. Here is the list of the main causes of a Rinnai error code 12, also related to "no flame" and flame failure:Īn error code 12 found on the Rinnai tankless water heater means " no flame" or a water heater didn’t recognize a flame in the combustion chamber. It can be found on all models, including V, RU, RL, and RUR series. For superseded products please contact Rinnai to confirm product information.An error code 12 is one of many Rinnai diagnostic codes used to identify problems in your Rinnai tankless water heater. This information may be different for superseded products.

rinnai energysaver 1004f blinking red light

The product information on this website (comprising product brochures, warranty information, installation manuals, diagrams, specifications and representations) relates to current products. Economy mode – allows the heater to modulate down one hour after the set temperature is reached, reducing running costs with no noticeable change in temperature.Pre-heat mode – pre-heats the room up to 1 hour prior to set programmed time.Dual digital timers – provide on and off programming for mornings and evenings.Inbuilt humidifier tray – for greater comfort.Power flue – allows for multiple installations.Zero emissions – perfect for those with allergies or respiratory problems.What’s more, its room sealed power flue system makes the 309FT ideal for bedrooms. The Energysaver 309FT is our smallest model, and thanks to its compact size it can fit into the tightest spaces.